TD-100345.doc
71
History bits
The <<history bits>> gives you a history of the errors the machine has had. The history bits
are cleared with the next writing of a service stamp.
User Terminal Screen Terminal
Press history bits key Read data for machine configuration.
PLEASE WAIT
COFFEE è TERMINAL
The individual history bits can be
viewed using the cursor keys
0= No error
1= Error present
HISTORY BIT
0 ENCOR
Further Bits......look at caption HISTORY
1 COFFEE SENSOR
TERMINAL READY
DATA LOADED
Possible mistakes:
No communication ERROR
READ ERROR
Wrong device type e.g. F700 Test1 not allowed F700 TEST 1 INVALID
Press Enter or ESC Text as before error TERMINAL READY
DATA LOADED
Legend history bits
History bits Cause
Encoder No encoder signal (Channel Error)
Coffee sensor Sensor thermoblock coffee / Hot water faulty
Steam sensor Sensor thermoblock steam faulty
De-scaling De-scaling terminated
Position Position cannot be approached
Initialization Initialization not possible
Fluid system Flowmeter timeout, although tank float indicates that there is water
Service stamp
This menu is required by the service technicians. The history bits are cleared with the next
writing of a service stamp.
User Terminal Screen Terminal
S1 Service stamp key Date
Navigation as for Config. keys
Entry with Enter, line 1 flashes
Change with numerical keyboard
DATE
D:22 M:09 Y:1999
S2 Diagnosis No.
Cannot be changed.
Display only IDENTIFICATION
12345
S3 Major error
Entry with Enter, line 1 flashes
Change with numerical keyboard
0-999 SERVICE STAMP
000 MAJOR ERROR
S4 Error 2
Entry with Enter, line 1 flashes
Change with numerical keyboard
0-999 SERVICE STAMP
000 ERROR 2
S5 Error 3
Entry with Enter, line 1 flashes
Change with numerical keyboard
0-999 SERVICE STAMP
000 ERROR 3
S6 Error 4
Entry with Enter, line 1 flashes
Change with numerical keyboard
0-999 SERVICE STAMP
000 ERROR 4
S7 Work 1
Entry with Enter, line 1 flashes
Change with numerical keyboard
0-999 SERVICE STAMP
000 WORK 1

Table of Contents

Other manuals for Franke Flair

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Franke Flair and is the answer not in the manual?

Franke Flair Specifications

General IconGeneral
TypeEspresso Machine
Pump Pressure15 bar
Product TypeCoffee Maker
BrandFranke
ModelFlair
Voltage220-240 V
Frequency50-60 Hz
MaterialStainless Steel
ProgrammableYes
Auto Shut-offYes
Filter TypeMetal Filter
Coffee OutputSingle or Double Espresso

Related product manuals