5-113
Table 5.1 Light Alarm Selection 1 (H81), Bit Assignment of Selectable Factors
Bit Code Content Bit Code Content
15 7
0l3
Overload of motor 3
14 6
0l2
Overload of motor 2
13
erp
RS-485 communications error
(COM port 2)
5
0l1
Overload of motor 1
12
er8
RS-485 communications error
(COM port 1)
4
dbh
Braking resistor overheated
11
er5
Option error 3
10
er4
Option communications error 2
0h3
Inverter internal overheat
9 1
0h2
External alarm
8
0l4
Overload of motor 4 0
0h1
Heat sink overheat
Table 5.2 Light Alarm Selection 2 (H82), Bit Assignment of Selectable Factors
Bit Code Content Bit Code Content
15 7
lif
Lifetime alarm
14 6
0h
Heat sink overheat early warning
13
cnT
Inverter life (Number of startups) 5
0l
Motor overload early warning
12
rTe
Inverter life
(Cumulative motor run time)
4
fal
DC fan locked
11
pTc
PTC thermistor activated 3
10
uTl
Low torque output 2
9
pid
PID alarm 1
8
ref
Reference command loss detected 0
ere
Speed mismatch or excessive speed
deviation
Table 5.3 Display of Light Alarm Factor
(Example) Light alarm factors "RS-485 communications error (COM port 2)," "RS-485 communications error (COM port 1),"
"Option communications error," "Overload of motor 1" and "Heat sink overheat" are selected by H81.
LED No. LED4 LED3 LED2 LED1
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Code
erp er8 er5 er4
0l4 0l3 0l2 0l1 dbh
0h3 0h2 0h1
Binary 0 0 1 1 0 1 0 0 0 0 1 0 0 0 0 1
Hexa-
decimal
(See Table 5.4.)
3
4
2
1
Example
Hexa-
decimal on
the LED
monitor
Hexadecimal expression
A 4-bit binary number can be expressed in hexadecimal format (1 hexadecimal digit). The table below shows the
correspondence between the two notations. The hexadecimals are shown as they appear on the LED monitor.
Table 5.4 Binary and Hexadecimal Conversion
Binary Hexadecimal Binary Hexadecimal
0 0 0 0
0
1000
8
0 0 0 1
1
1001
9
0 0 1 0
2
1010
a
0 0 1 1
3
1011
b
0 1 0 0
4
1100
c
0 1 0 1
5
1101
d
0 1 1 0
6
1110
e
When the H26 data is set to "1" (PTC (The inverter immediately trips with
0h4
displayed)), if the PTC
thermistor is activated, the inverter stops without displaying
l-al
, blinking the KEYPAD CONTROL LED,
or outputting
L-ALM signal, regardless of the assignment of
b
it 11 (PTC thermistor activated) by H82 (Light
Alarm Selection 2).
Light alarm--L-ALM (E20 to E24 and E27, data = 98)