5-25
Table A Factory Default According to Shipping Destination
Shipping destination
Asia EU
FRN_ _ _G1
-2A FRN_ _ _G1
-4A FRN_ _ _G1
-4E
Function code Name
200 V class series 400 V class series 400 V class series
F03, A01, b01, r01
E31, E36, E54
Maximum frequency
Frequency detection (Level)
60.0 Hz 50.0 Hz 50.0 Hz
F05, A03, b03, r03
F06, A04, b04, r04
Rated voltage at base frequency
Maximum output voltage
220 V 415 V 400 V
Note: A box (
) in the above table replaces S or E depending on the enclosure.
Table B Factory Defaults Depending upon Inverter Capacity
Inverter
capacity
(kW)
Torque boost 1 to 4
F09/A05/b05/r05
Auto-restart after
momentary power failure
H13
Inverter
capacity
(kW)
Torque boost 1 to 4
F09/A05/b05/r05
Auto-restart after
momentary power failure
H13
0.4 7.1 55
0.75 75
1.5 90
2.2
6.8
110
1.5
3.7 (4.0)* 5.5 132
5.5 4.9 160
2.0
7.5 4.4
0.5
200
11 3.5 220
15 2.8 280
2.5
18.5 315
22
2.2
355
4.0
30 400
37
1.0
500
45
0.0
1.5 630
0.0
5.0
* 4.0 kW for the EU.