4-6
When accessing the function code P02*, take into account that changing the P02* data automatically updates the data
of the function codes P03*, P06* to P23*, P53* to P56*, and H46.
The motor rating should be specified properly when performing auto-torque boost, torque calculation monitoring,
auto energy saving, torque limiting, automatic deceleration (anti-regenerative control), auto search for idling moto
r
speed, slip compensation, torque vector control, droop control, or overload stop.
In any of the following cases, the full control performance may not be obtained from the inverter because the moto
r
parameters differ from the factory defaults, so perform auto-tuning. (Refer to Section 4.1.7.)
The motor to be driven is not a Fuji product or is a non-standard product.
The wiring distance between the inverter and the motor is too long (generally 20 m or more).
A reactor is inserted between the inverter and the motor.
4.1.7 Function code basic settings and tuning < 2 >
Under the V/f control (F42* = 0 or 2) or dynamic torque vector control (F42* = 1), any of the following cases requires
configuring the basic function codes given below and auto-tuning. (Refer to Figure 4.1 on page 4-1.)
- Driving a non-Fuji motor or non-standard motor
- Driving a Fuji general-purpose motor, provided that the wiring distance between the inverter and motor is long or a reactor is
connected
Configure the function codes listed below according to the motor ratings and your machinery design values. For the motor
ratings, check the ratings printed on the motor's nameplate. For your machinery design values, ask system designers about
them.
For details on how to modify the function code data, see Chapter 3, Section 3.4.2 "Setting up function codes -- Menu #1
"Data Setting" --."
Factory default
Function
code
Name Function code data
FRN_ _ _G1-2A/4A FRN_ _ _G1-4E
f
04
*
Base frequency 1
200 V class series:
60.0 (Hz)
400 V class series:
50.0 (Hz)
200 V class series:
400 V class series:
50.0 (Hz)
f
05
*
Rated voltage
at base frequency 1
200 V class series:
220 (V)
400 V class series:
415 (V)
200 V class series:
400 V class series:
400 (V)
p
02
*
Motor 1
(Rated capacity)
Nominal applied motor capacity
p
03
*
Motor 1
(Rated current)
Motor ratings
(printed on the nameplate of the
motor)
Rated current of nominal applied motor
f
03
*
Maximum frequency 1
200 V class series:
60.0 (Hz)
400 V class series:
50.0 (Hz)
200 V class series:
400 V class series:
50.0 (Hz)
f
07
Acceleration time 1
(Note)
22 kW or below: 6.00 (s)
30 kW or above: 20.00 (s)
f
08
Deceleration time 1
(Note)
Machinery design values
(Note) For a test-driving of the motor,
increase values so that they are longer
than your machinery design values. If
the specified time is short, the inverter
may not run the motor properly.
22 kW or below: 6.00 (s)
30 kW or above: 20.00 (s)
When accessing the function code P02*, take into account that changing the P02* data automatically updates the data