8-12
Dimensions (mm)
Power
supply
voltage
Nominal
applied
motor
Inverter type
FRN_ _ _G1
-2/4
LD/
MD/LD
mode
Reactor
Refer
to:
W W1 D D1 D2 D3 H
Mounting
hole
Terminal
hole
Mass
(kg)
220 LD
280
HD
DCR4-280C 350±10 310 161±4 133 210 80.5±2190 36
280
MD
315
315 HD
DCR4-315C 146±4118 73±1
M16
40
280 LD
315 MD
355
355 HD
DCR4-355C
400±10 345
156±4128
200
78±1
225
47
315 LD
355 MD
400
400 HD
DCR4-400C 455±10 145±4 117 213 72.5±152
355 LD
450
MD
DCR4-450C 440±10
385
150±4122215 75±260
400
LD
500
HD
DCR4-500C
Figure
B
445±10 390 165±4 137 220 82.5±2
245
M10
70
500
LD
630
HD
DCR4-630C 285±10 145 203±4 170 195 104±275
400 V
710
630
LD DCR4-710C
Figure
C
340±10 160 295±4 255 225 107±2
480 M12
Ø15
95
Note 1: A box () in the above table replaces S or E depending on the enclosure.
A box () in the above table replaces A or E depending on the shipping destination.
Note 2: Inverters with a capacity of 55 kW in LD mode and inverters with 75 kW or above in all modes require a DCR to be connected.
Figure A Figure B
(Unit: mm)
Figure C
2
x
Terminal
hole
4
x
Mounting
hole
2 x 4
x
Terminal
hole
4
x
Mounting
hole
2
x
4
x
Terminal hole
4
x
Mounting hole
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net