3-17
Chap. 3 OPERATION USING THE KEYPAD
Table 3.15 Display Items in "Maintenance Information" (Continued)
LED Monitor
shows:
Item Description
5_30
Cumulative run time of motor 4
Shows the content of the cumulative power-ON time counter of motor 4.
The display method is the same as for
5_23
above.
5_31
Remaining time before the next
motor 1 maintenance
Shows the time remaining before the next maintenance, which is
estimated by subtracting the cumulative run time of motor 1 from the
maintenance interval specified by H78. (This function applies to motor 1
only.)
Display range:
0
to
9999
The x10 LED turns ON.
Time remaining before the next maintenance (hour) =
Displayed value
× 10
5_32
Number of startups 2
Shows the content of the motor 2 startup counter (i.e., the number of run
commands issued).
The display method is the same as for
5_08
above.
5_33
Number of startups 3
Shows the content of the motor 3 startup counter (i.e., the number of run
commands issued).
The display method is the same as for
5_08
above.
5_34
Number of startups 4
Shows the content of the motor 4 startup counter (i.e., the number of run
commands issued).
The display method is the same as for
5_08
above.
5_35
Remaining startup times before
the next maintenance 1
Shows the startup times remaining before the next maintenance, which is
estimated by subtracting the number of startups from the preset startup
count for maintenance specified by H79. (This function applies to motor 1
only.)
The display method is the same as for
5_08
above.
5_36
Light alarm factor (Latest)
Shows the factor of the latest light alarm as an alarm code.
For details, refer to Chapter 6, Section 6.1 "Protective Functions."
5_37
Light alarm factor (Last)
Shows the factor of the last light alarm as an alarm code.
For details, refer to Chapter 6, Section 6.1 "Protective Functions."
5_38
Light alarm factor (2nd last)
Shows the factor of the 2nd last light alarm as an alarm code.
For details, refer to Chapter 6, Section 6.1 "Protective Functions."
5_39
Light alarm factor (3rd last)
Shows the factor of the 3rd last light alarm as an alarm code.
For details, refer to Chapter 6, Section 6.1 "Protective Functions."
5_40
Option error factor 1
Shows the factor of the error that has occurred in the option being
connected to the A-port.
5_41
Number of option errors 2
Shows the total number of errors that have occurred in the option being
connected to the B-port.
Once the count exceeds 9999, the counter will be reset to "0."
5_42
Option error factor 2
Shows the factor of the error that has occurred in the option being
connected to the B-port.
5_43
Number of option errors 3
Shows the total number of errors that have occurred in the option being
connected to the C-port.
Once the count exceeds 9999, the counter will be reset to "0."
5_44
Option error factor 3
Shows the factor of the error that has occurred in the option being
connected to the C-port.