6.5 SX Bus Interface Card
6-107
Chap. 6
CONTROL OPTIONS
Dynamic SW1
(MSB) (LSB)
15 14 1312 11 1098765432 1 0
SW16
UPAC
SW15
UPAC
SW14
UPAC
SW13
UPAC
SW12
UPAC
SW11
UPAC
SW10
UPAC
SW9
UPAC
SW8
UPAC
SW7
UPAC
SW6
UPAC
SW5
UPAC
SW4
UPAC
SW3
UPAC
SW2
UPAC
SW1
Dynamic SW2
(MSB) (LSB)
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
- - - - -
UPAC
SW30
UPAC
SW29
UPAC
SW28
UPAC
SW27
UPAC
SW26
SW22 SW21 SW20 SW19 SW18 SW17
Each bit operation of the dynamic SW reflects the control variable or modifies function code data.
1: Enabled (UPAC switch is enabled and the control variable data is reflected.)
0: Disabled (UPAC switch is disabled and the control variable data is not reflected.)
Note: The dynamic switches to be used on the UPAC option are different from the above dynamic
switches in bit assignment and ON/OFF definition. Be careful.
By default, all dynamic switches are set to 0 (disabled). When the control variable
(MICREX-SXVG) is enabled in the UPAC compatible format, be sure to enable the
corresponding dynamic switch.
Refer to the UPAC SW shown in the control block diagram in Chapter 4 for the position of
each dynamic switch.
SW name
Switching target
Corresponding control
block
UPAC SW1
:
Speed setting 1/Frequency command (for V/f) 4.1.2
UPAC SW2 : Torque command 1 4.1.6
UPAC SW3 : Torque current command 4.1.7
UPAC SW4 : Magnetic flux command 4.1.7
UPAC SW5 : Control data (CW) 4.1.1
UPAC SW6 : FRENIC-VG DO1(standard + DIOA: 13 bits) 4.1.12, 4.1.13
UPAC SW7 : Acceleration time 4.1.3
UPAC-SW8 : Deceleration time 4.1.3
UPAC SW9 : Torque limiting value level 1 4.1.7
UPAC SW10 : Torque limiting value level 2 4.1.7
UPAC SW11 : Speed setting 4/Frequency command (for V/f) 4.1.6
UPAC SW12 : Torque command 2 4.1.7
UPAC SW13 : Torque bias 4.1.6
UPAC SW14 : Speed supplement command 4.1.3
UPAC SW15 : Actual speed (simulated) 4.1.4
SW16 : Selecting function code 1 address -
SW17 : Selecting function code 1 data -
SW18 : Selecting function code 2 address -
SW19 : Selecting function code 2 data -
SW20 : Polling function code 1 address -
SW21 : Polling function code 2 address -
SW22 to SW24 : Reserved -
SW25 : FRENIC-VG DO2(DIOB option: 10 bits) -
UPAC SW26 : FRENIC-VG AO (AO1) 4.1.14
UPAC SW27 : FRENIC-VG AO (AO2) 4.1.14
UPAC SW28 : FRENIC-VG AO (AO3) 4.1.14
UPAC SW29 : FRENIC-VG AO (AIO option AO4) 4.1.14
UPAC SW30 : FRENIC-VG AO (AIO option AO5) 4.1.14
SW30, SW31 : Reserved -