5.3.4 Communication examples
This section illustrates representative communication examples. (In all cases, the station number is
5.)
5.3.4.1 Reading
(1) M06: Read speed detection value.
Query
(Host J Inverter)
05 03 08 06 00 01 67 EF
Normal response
(Inverter J Host)
05 03 02 27 10 53 B8
Speed detection value: 2710
H
J 10000d
Max. speed
10000d x
20000
= 750 (r/min)
(Max. speed: 1500 r/min)
(2) S01: Write 400 r/min to speed setting 1. (Max. speed: 1500 r/min)
20000d
400 (r/min) x
1500
(r/min)
= 5333d = 14D5
H
Query
(Host J Inverter)
05 06 07 01 14 D5 16 65
Normal response (Inverter J Host)
05 06 07 01 14 D5 16 65