6.7 CC-Link Interface Card
6-171
Chap. 6
CONTROL OPTIONS
6.7.8.3 Monitor code/command code (o32=0) in VG7 compatible mode
Table 6.7.17 Monitor Code (o32 = 0)
Code No. Description Unit Remarks
0000
H
No monitoring (Fixed to 0)
0001
H
Output frequency 0.01 Hz In units of 0.1 Hz
0002
H
Output current 0.1 A
0003
H
Output voltage 0.1 V
0004
H
No monitoring (Fixed to 0)
0005
H
Speed setting 1 r/min
0006
H
Operation speed 1 r/min
0007
H
Torque command value 0.1%
0008
H
DC link bus voltage 0.1 V In units of 1 V
0009
H
000D
H
No monitoring (Fixed to 0)
000E
H
Motor output 0.01 kW In units of 0.1 kW
000F
H
Operation command
0010
H
Output terminate status
0011
H
Torque current command value 0.1%
0012
H
Flux command 0.01%
0013
H
Position detection pulse 1 pulse Quad multiplication of built-in PG
0014
H
Cumulative run time (Cumulative power-ON
time)
1 hr
0015
H
0019
H
No monitoring (Fixed to 0)
Detailed description on operation command
b15 b8 b7 b0
RST X14 X13 X12 X11 X9 X8 X7 X6 X5 X4 X3 X2 X1 REV FWD
Figure 6.7.14
Detailed description on output terminate status
b15 b8 b7 b0
Y18 Y17 Y16 Y15 Y14 Y13 Y12 Y11 - - - Y5A Y4 Y3 Y2 Y1
- : Empty (Fixed to 0)
Figure 6.7.15