6-172
Table 6.7.18 Command Code (o32 = 0)
Item
Code
number
Description Remarks
Operation mode read Note 1 007B
H
0000
H
: Link operation (CC-Link)
0001
H
: Terminal command for external
drive
0002
H
: Keypad operation
0000
H
: ([LE]=ON, H300, and remote
mode)
0001
H
: ([LE]=OFF or H30=0), F02=1 and
remote mode
0002
H
: (([LE]=OFF or H30=0), F02=0) or
local mode
Writing of operation mode
Note 1, Note 4
00FB
H
0000
H
: Link operation (CC-Link)
0001
H
: Terminal command for external
drive
0000
H
: LE=ON
0001
H
: LE=OFF
• Assignment of LE to
terminal X gives
priority to the
terminal.
• 0 with the power
turned OFF
Reading of alarm history No.1/No.2 0074
H
Reading of history No. 1/history No.2 L byte: History No.1, H byte: History No.2
Reading of alarm history No.3/No.4 0075
H
Reading of history No.3/history No.4 L byte: History No.3, H byte: History No.4
Reading of alarm history No.5/No.6 0076
H
Reading of history No.5/history No.6 L byte: History No.5, H byte: History No.6
Reading of alarm history No.7/No.8 0077
H
Reading of history No.7/history No.8 L byte: History No.7, H byte: History No.8
Reading of speed command 006D
H
Read speed command
Writing of speed command 00ED
H
Write speed command
0 to ±20000 (Max. with ±20000)
Also accessible from remote register
Reading of function code 0000
H
to
0063
H
Writing of function code Note 2 0080
H
to
00E3
H
Read or write link Nos. 0 to 255 by the
combinations with link parameter
extension setting.
For the link No./data format, refer to
Chapter 4, Section 2 "Function Code List."
Reset alarm 00FD
H
9696
H
: Reset the alarm. Only during link operation
Read 007F
H
Note 3 Link parameter
extension setting
Write 00FF
H
Note 3
For selection of the area accessed by
reading/writing function codes
0000
H
: Link Nos. 0 to 99
0001
H
: Link Nos. 100 to 199
0002
H
: Link Nos. 200 to 255
Note 1: Link operation selection [LE] is switched by switching the operation mode from CC-Link, as follows.
0
1
ON
OFF
w/o
w
w
w/o
[LE]
Terminal X [LE] status
Operation mode[FB
H
]
(0 with the power turned OFF)
OPC-VG1-CCL
mounted
Assignment of
LE to terminal X
Figure 6.7.16 Link Operation Selection [LE] with CC-Link Used
Note 2: Writing a function code sets a value given by adding the offset value of 80
H
to the link No.
Example: Function code "F03: M1 maximum speed" Link 51
H
The command code for reading the function code is "51
H
". The function code for writing function code is "D1
H
", which is
obtained by adding the offset value of 80
H
.
Note 3: With code 007F, read the extension code setting. With code 00FF, write extension code setting.
Note 4: In local mode, running mode cannot be changed.
Table 6.7.19 Response Code (o32=0)
Code number Item Description
0000
H
Normal (No error) Command code execution normally completed
0001
H
Write mode error ・Function code was written while the inverter was running
・Function code was written while EEPROM was being written.
・Function code was written at the time of transmission error.
・S code was written when upper link was enabled.
・Function code was written in a mode where edition is not permitted.
0002
H
Function code selection error An inaccessible link No. was set.
0003
H
Out of setting range Set data is out of changeable range.