6.12  DIO Expansion Card 
6-235 
Chap. 6 
CONTROL OPTIONS 
6.12.5.2 DIOB selected 
Only the use of the OPC-VG1-UPAC as another option (available soon) will make it possible to operate 
the following functions. 
DIOB functions are allocated to control variables (to be specific, global variables allocated to the control 
variables) that will be available at the time of selecting a six-unit FRENIC-VG system. 
To use DIOB functions, select the corresponding control variables from the list of control variables or 
specify the address (%IQ area) of each DIOB function and register the control variable, and check the box 
in the system definition. 
The optional OPC-VG1-SIU module is required to operate DIOB options INV2 through INV6. 
Table 6.12.7 
Address No 
Area 
Name Data category 
Type 
Direction 
 
         
%IW1.13  14  INV1  DI control of INV1 (DIOB option; 16 bits) Data category; 26 W 
%IW2.13  14  INV2  DI control of INV2 (DIOB option; 16 bits) Data category; 26 W 
%IW3.13  14  INV3  DI control of INV3 (DIOB option; 16 bits) Data category; 26 W 
%IW4.13  14  INV4  DI control of INV4 (DIOB option; 16 bits) Data category; 26 W 
%IW5.13  14  INV5  DI control of INV5 (DIOB option; 16 bits) Data category; 26 W 
%IW6.13  14  INV6  DI control of INV6 (DIOB option; 16 bits) Data category; 26 W 
The UPAC is in DI 
control of INV1 
through INV6. Used 
by INV1 through 
INV6. 
        
INV12,3,4,5,6UPAC 
 
         
%QW1.41  24  INV1  DO control of INV1 (DIOB option; 10 bits) Data category; 27 W 
%QW2.41  24  INV2  DO control of INV2 (DIOB option; 10 bits) Data category; 27 W 
%QW3.41  24  INV3  DO control of INV3 (DIOB option; 10 bits) Data category; 27 W 
%QW4.41  24  INV4  DO control of INV4 (DIOB option; 10 bits) Data category; 27 W 
%QW5.41  24  INV5  DO control of INV5 (DIOB option; 10 bits) Data category; 27 W 
%QW6.41  24  INV6  DO control of INV6 (DIOB option; 10 bits) Data category; 27 W 
The UPAC is in DO 
control of INV1 
through INV6. Used 
by INV1 through 
INV6. 
        
UPACINV1,2,3,4,5,6