6-122
Table 6.6.2 Plastic Optical Fiber Cable Specifications
Item Min. Max. Unit Remarks
Storage temperature
range
-40 +75 °C
Tension 50 N 30 minutes or less
Short-time bending
radius
10 - mm
Will stop operation within one hour and the inter-inverter link
error
erb
occurs.
Long-time bending
radius
35 - mm
If bent for 35 mm or less for a long period of time, the
inter-inverter link error
erb
may occur. Curvature should be
kept 35 mm or more.
Tensile strength
(long time)
- 1 N
Flexibility - 1000 Times Bend for 90 degrees on 10 mm mandrel (core bar, main axis)
Shock - 0.5 kg
Shock test is in accordance with MIL-1678, Mothod2030,
Procefurel.
Guaranteed minimum
distance
10 m
Minimum guaranteed value due to transmission loss (0 to
70°C)
Weight 4.6 g/m