6-200
Green
Pin No. 1 2 3 4 5 6 Case
Green
Red Black Orange Orange/white Sky blue
Sky
blue/white
Protection tube
White Black Yellow Brown Red Blue
Signal name P5 M5 BAT+ BAT SIG+
1
SIG
2
For green, either 1) or 2) is applicable.
1 Connect the negative logic side of the communications signal.
2 Connect the positive logic side of the communications signal.
(Illustration B)
Connector model
Connector on the
inverter side
Connector on the motor
side
Plug housing main unit 54180-0619
Cap housing 1-172332-9
Plug shell cover 58299-0626
Socket 170361-1
Plug shell body 58300-0626
Cover (X2) 316455-1
Plug mold cover (A) 54181-0615
Screw (X2) XPB M2.6×10
Plug mold cover (B) 54182-0605
Nut (X2) M2.6
Cable clamp 58303-0000
Manufactured by Tyco Electronics
Clamp screw 59832-0009
Manufactured by Molex
Green
Option card side 1 2 3 4 5 6 Shell
Motor side 7 8 1 2 5 4 3
Green Red Black Orange
Orange/
white
Blue/white Blue Shield
White Black Yellow Brown Blue Red Shield
Signal name P5 M5 BAT+ BAT- SIG+
*
1
SIG
*
2
FG
*1: Connect the negative logic side of the communications signal.
*2: Connect the positive logic side of the communications signal.
* When you prepare cables, the following electric wires are recommended.
Recommended electric wires
When the cable length is 10 m or less: RMCV-SB-A-AWG#25/2P+AWG#23/2C or AWG#23/3P
When the cable length is more than 10 m and less than or equal to 50 m: RMCV-SB-A AWG#25/2P+AWG#17/2C or the
equivalent

Table of Contents