194 Upgrade and Maintenance Manual TX100 S3 Core Edition
System board and components
Safety notes
V CAUTION!
The CMOS battery must be replaced with an identical battery or with
a battery type recommended by the manufacturer.
Keep lithium batteries away from children.
Do not throw batteries into the trash can. Lithium batteries must be
disposed of in accordance with local regulations concerning special
waste.
For further safety information, please refer to section "Environmental
protection" in the PRIMERGY TX100 S3 Core Edition Operating
Manual.
Ensure to insert the CMOS battery the with the positive pole
facing up!
14.1.1 Required tools
Preliminary and concluding steps: tool-less
Main steps: tool-less; recommended: tooth pick
14.1.2 Preliminary steps
Before replacing the CMOS battery, perform the following steps:
Ê Shut down the server as described in section "Shutting down the server" on
page 40.
Ê Remove the AC power cord from the cable tie and disconnect it from the
system as described in section "Disconnecting the power cord" on page 41.
Ê Bring the server to its horizontal position.
Ê Open the side cover as described in section "Removing the side cover" on
page 43.
Ê Remove the HDD cage as described in section "Removing the HDD cage"
on page 60.