190-01115-01 G3X™/G3X Touch™ Avionics Installation Manual
Rev. AV Page H-46
10. Go to the AP page in configuration mode and navigate to the Pitch Servo sub-section to configure
the servo direction.
a) The Servo Direction should be set to Normal. The servo arm should move clockwise to
cause a nose down elevator movement and the servo arm should move counterclockwise to
cause a nose up elevator movement.
Figure H-7 Normal Pitch Servo Direction
b) The Servo Direction should be set to Reverse and the servo arm should move clockwise to
cause a nose up elevator movement and the servo arm should move counterclockwise to
cause a nose down elevator movement.