GE HEALTHCARERAFT VOLUSON E8 / VOLUSON E6
D
IRECTION KTD102576, REVISION 7 DRAFT (AUGUST 23, 2012) SERVICE MANUAL
7-40 Section 7-9 - Error Messages
PowerManager: HRS not initialized restart the system
PowerSpecBuffer memory allocation failed. Action: restart the system restart the system
PRF_GeneratorBoundary: BBC Ensemble Limitation out of limit.
Action: restart the system
restart the system
PRF_GeneratorBoundary: BBCPW Ensemble Limitation out of limit
Action: restart the system
restart the system
Probe () doesn't contain correct ProbeVersion! Action: Please contact online center Please contact technical support
Probe Scan Function Not Supplied restart the system
Probe with Probe-ID xx not supported. On Attempt to read Probe-ID from an invalid
probe connector. Action: restart system
Connect another probe
Probe with Probe-ID xx not supported on left probe connector (A). Connect another probe
Probe with Probe-ID xx not supported on middle probe connector (B). Connect another probe
Probe with Probe-ID xx not supported on right probe connector (C). Connect another probe
Probe with Probe-ID xx not supported on upper-left probe connector (CW). Connect another probe
Probe-ID valid, but Flexible-EEPROM-Datamodel not implemeted yet.
On Attempt to read Probe-ID from an invalid probe connector. Action: restart system
restart the system
Probe-ID valid, but Flexible-EEPROM-Datamodel not implemeted yet on left probe
connector (A).
Probe-ID valid, but Flexible-EEPROM-Datamodel not implemeted yet on middle
probe connector (B).
Probe-ID valid, but Flexible-EEPROM-Datamodel not implemeted yet on right probe
connector (C).
Probe-ID valid, but Flexible-EEPROM-Datamodel not implemeted yet on upper-left
probe connector (CW).
PW Archive::not implemented Action: restart the system
PW_BaseLinePos Out Of Range press ok and save this user-setting once again
PW_BurstCalcBlock: UserProgApplication out of range. Action: restart system restart the system
PW_CW_FFT_FactBlock: DSC_ScrollX_Zoom darf nicht kleiner als eins sein! restart the system
PW_Dynamic Out Of Range press ok and save this user-setting once again
PW_Reject Out Of Range press ok and save this user-setting once again
PWCW-DSC:Memory allocation failed restart the system
PWGain Out Of Range press ok and save this user-setting once again
PWM-Acoustic value not defined. Action: Please call technical support Please call technical support
RawDataSynthesizer : memory allocation failed restart the system
Regional settings for Numbers/Decimal symbol has been changed back to '.' No action required (for information only)