—————— Instruction manual ——————
235
andtheprevious referencevalueis maintained.The output
oftheMotorpotentiometerfunctionvarieswiththesetramp
times.Thepreviousreferencevalueisrestoredwhenthereset
commandisremoved.
InpRefZero setsInp=0andRef=0i.e.adenitivereferencesettingis
performed.Theoutputof theMotorpotentiometerfunction
varieswiththesetramptimes.
InpRefLowLimit setsInp=lowlimandRef=lowlimi.e.adenitivereference
settingisperformed.TheoutputoftheMotorpotentiometer
functionvarieswiththesetramptimes.
OutZero setsOut=0i.e.atemporaryoutputsettingfortheMotorpoten-
tiometerfunctionisperformed.Thepreviousreferencevalueis
maintained.Iftheresetcommandisenabled,theoutputofthe
Motorpotentiometerfunctioncontinuestobe=0,ifthereset
commandisnotenabledtheoutputoftheMotorpotentiometer
functionvarieswiththesetramptimes.
OutLowLimit setsOut=lowlimi.e.atemporarysettingfortheoutputof
theMotorpotentiometerfunctionisperformed.Theprevious
referencevalueismaintained.Iftheresetcommandisenabled,
theoutputoftheMotorpotentiometerfunctioncontinuesto
be=lowlimit,iftheresetcommandisnotenabledtheoutput
oftheMotorpotentiometerfunctionvarieswiththesetramp
times.
OutRefZero setsOut=0i.e.adenitivesettingfortheoutputoftheMotor
potentiometerfunctionisperformed.
OutRefLowLimit setsOut=lowlimi.e.adenitivesettingfortheoutputofthe
Motorpotentiometerfunctionisperformed.
InpUpLimit setsInp=upperlimi.e.atemporarysettingforthereference
isperformedandthepreviousreferencevalueismaintained.
TheoutputoftheMotorpotentiometerfunctionvarieswiththe
setramptimes.Thepreviousreferencevalueisrestoredwhen
theresetcommandisremoved.
InpRefUpLimit setsInp=upplimandRef=upplimi.e.adenitivereference
settingisperformed.TheoutputoftheMotorpotentiometer
functionvarieswiththesetramptimes
InpFreeze WhenInpFreezeinputisset,theUpandDown commandsare
temporarilydisabled.