3-4
Recorder Mode
3.2 Amp Settings
(1)
(9) (10)
(2) (3) (4) (5) (6)
(8)
(7)
Amp Settings
(1) CH ............................ Indicates the channel number.
(2) AMP .......................... Displays the type of amplifier installed
V : WR3-V (Voltage) amp
M : WR3-M (Multi-input) amp
DCB : WR3-DCB (DC strain) amp
FV : WR3-FV (Frequency-to-voltage conversion) amp
(3) Input.......................... Selects the input coupling status. The available settings vary with the type of amp
installed.
Available Settings: WR3-V amp
Off : No signal input is accepted.
AC : Used for measuring an alternating-current component of signal input that
also contains a direct-current component.
DC : Used for measuring direct-current voltage.
GND : Measures the 0-V line instead of measuring changes in the signal input.
CAL : Generates a calibration voltage that is 1/2 full scale of the currently
selected range instead of measuring the input voltage.
Available Settings: WR3-M amp
Off : No signal input is accepted.
AC : Used for measuring an alternating-current component of signal input that
also contains a direct-current component.
DC : Used for measuring direct-current voltage.
TEMP : Used for measuring temperature.
GND : Measures the 0-V line instead of measuring changes in the signal input.
CAL : Generates a calibration voltage that is 1/2 full scale of the currently
selected range instead of measuring the input voltage.
Available Settings: WR3-DCB amp
Off : Select this setting if you do not wish to perform measurement.
DC : Select DC to measure the strain sensor's output voltage in DC coupling
status.
ZERO : Select ZERO to check the zero-point position
CAL+ : Select CAL+ to check the "+1/2 full-scale" position of the measurement
range.
CAL– : Select CAL+ to check the "–1/2 full-scale" position of the measurement
range.