260
SETTINGS
June 1999
96-8000
15 H & T CODE AGREEMENT
This is an On/Off setting. When it is off, no special functions occur. When it is set to on, a check is made to
ensure that the H offset code matches the tool presently in the spindle. This check can help to prevent
crashes. In program restart this check is not done until motion begins.
16 DRY RUN LOCK OUT
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the DRY RUN function
cannot be turned on.
17 OPT STOP LOCK OUT
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the OPTIONAL STOP
function cannot be turned on.
18 BLOCK DELETE LOCK OUT
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the BLOCK DELETE
function cannot be turned on.
19 FEED RATE OVERRIDE LOCK
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the feed rate override
buttons are locked out.
20 SPINDLE OVERRIDE LOCK
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the spindle speed
override buttons are locked out.
21 RAPID OVERRIDE LOCK
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the rapid speed
override buttons are locked out.
22 CAN CYCLE DELTA Z
This is a decimal numeric entry. It must be in the range of 0.0 to 29.9999 inches. This setting specifies the
delta Z used in the G73 canned cycle when the Z-axis is moved up to clear chips.
23 9xxx PROGS EDIT LOCK
This is an On/Off setting. When it is off, the machine operates normally. When it is on, the 9000 series
programs (usually macro programs) are invisible to the operator and cannot be uploaded or download. They
also cannot be listed, edited, or deleted.
24 LEADER TO PUNCH
This setting is used to control the leader sent to a paper tape punch device connected to the first RS-232 port.
The values that can be selected are: NONE, BLANK, or NUL CHAR. None causes no extra data to be sent as
a leader. Blank causes two feet of blanks to be punched at the start of a program and one foot of blanks at the
end. Null causes the same thing as blanks but uses the ASCII code null which is all zero.
25 EOB PATTERN
This setting controls what is sent out and expected as input to represent the EOB (end of block) on serial port
one. The possible selections are: CR LF, LF only, CR only, or LF CR CR.