5 June 2020 CasTemp Wireless including CasTemp Superheat Page 20
9.4.3.2.2 ASCII
Field name
Description
Data format
Message header
Id
1
1 Char
DataCount
8
2 Chars
Payload
Heat number
The heat number
8 Chars
Example
Heat number = ABCD1234
Field
Id
DataCount
Heat number
Char value
1
08
ABCD1234
Byte index
1
[2-3]
[4-11]
9.4.3.3 Time Synchronisation
CasTemp SuperHeat can accept a time input from the PLC which will match the time shown on
screen to the time that all the other plant equipment is calibrated to.
9.4.3.3.1 Byte
Field name
description
Data format
Message header
Id
2
Byte
DataCount
7
UShort
Payload
DateTime
The new datetime for the instrument
DateTimeFormat
Example
DateTime = 23/04/2019 15:09:54
Field
Id
DataCount
DateTime
Hex value
{02}
{00}{07}
{17}{04}{14}{13}{0F}{09}{36}
Byte index
1
[2-3]
[4-10]
9.4.3.3.2 ASCII
Field name
description
Data format
Message header
Id
2
1 Char
DataCount
7
2 Chars
Payload
DateTime
The new datetime for the instrument
DateTimeFormatASCII
Example
DateTime = 23/04/2019 15:09:54
Field
Id
DataCount
DateTime
Char value
2
16
2019042315:09:54
Byte index
1
[2-3]
[4-19]
9.4.3.4 Ladle Empty Time
Ladle Empty time is the dynamic time when the caster expects to be finished with the ladle. This is in
minutes format. Example (30) minutes until ladle empty