Door Contact
You can set the door sensor as remaining closed or
remaining open. Usually, it is remaining closed.
Exit Buon Type
You can set the exit buon as remaining closed or remaining
open. Usually, it is remaining open.
Door Locked Time
Aer swiping the normal card and relay acon, the mer for
locking the door starts working.
Extended Open
Duraon
The door contact can be enabled with appropriate delay
aer person with extended accesss needs swipes her/his
card.
Door Open Timeout Alarm
The alarm can be triggered if the door has not been closed
in a
congured me period. If it is set as 0, no alarm will be
triggered.
Lock Door when Door Closed
The door can be locked once it is closed even if the Door
Locked Time is not reached.
Duress Code
The door can open by inpung the duress code when there
is duress. At the same
me, the client can report the duress
event.
Super Password
The specic person can open the door by inpung the super
password.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer
of the card reader (by entering the dismiss code on the
keypad).
Note
•
The duress code, super code, and dismiss code should be
dierent.
•
The duress code, super password, and the dismiss code
should be dierent from the authencaon password.
•
The length of duress code, super password, and the dismiss
code is according the device, usually it should contains 4 to 8
digits.
5.
Click OK.
6.
Oponal: Click Copy to , and then select the door/oor(s) to
copy the parameters in the page to the selected
doors/oor(s).
Note
The door or oor's status duraon sengs will be copied to
the selected door/oor(s) as well.
Congure Parameters for Card Reader
Aer adding the access control device, you can congure its card
reader parameters.
52