View the default card reader authencaon mode.
Fingerprint Capacity
View the maximum number of available ngerprints.
Exisng Fingerprint Number
View the number of existed ngerprints in the device.
Score
The device will score the captured picture according to the
yaw angle, pitch angle, and pupillary distance. If the score is
less than the
congured value, face recognion will be
failed.
Face Recognion Timeout Value
If the
recognion me is more than the congured me, the
device will remind you.
Face Recognion Interval
The me interval between two connuous face recognions
when authencang. By default, it is 2s.
Face 1:1 Matching Threshold
Set the matching threshold when authencang via 1:1
matching mode. The larger the value, the smaller the false
accept rate and the larger the false
rejecon rate when
authencaon.
1:N Security Level
Set the matching security level when authencang via 1:N
matching mode. The larger the value, the smaller the false
accept rate and the larger the false
rejecon rate when
authencaon.
Live Face Detecon
Enable or disable the live face detecon funcon. If enabling
the funcon, the device can recognize whether the person is
a live one or not.
Live Face
Detecon Security Level
Aer enabling Live Face Detecon funcon, you can set the
matching security level when performing live face
authencaon.
Max. Failed Aempts for Face Auth.
Set the maximum live face detecon failed aempts. The
system will lock the user's face for 5 minutes if the live face
detecon is failed for more than the congured aempts.
The same user cannot authencate via the fake face within 5
minutes. Within the 5 minutes, the user can authencate via
the real face twice
connuously to unlock.
Lock Authencaon Failed Face
Aer enabling the Live Face Detecon funcon, the system
will lock the user's face for 5 minutes if the live face
detecon is failed for more than the congured aempts.
The same user cannot authencate via the fake face within 5
minutes. Within the 5 minutes, the user can
authencate via
the real face twice connuously to unlock.
Applicaon Mode
You can select indoor or others applicaon modes according
to actual environment.