98
_____________________________________________________________________________________________
5.2 Comparison Details
______________________________________________________________________________________________
Trigger mode: Single Trigger mode: Repeat or Auto
When the stop conditions are met after
comparison, the 8730-10, 8731-10 stops
measurement. Enable the auto save function
to save the data. If the stop conditions are
not met, the 8731-10, 8731-10 clears the
waveform and stands by again for the trigger.
When the stop conditions are met after
comparison, the 8730-10, 8731-10 stops
measurement and stands by for the trigger.
Enabling the auto save function saves the
data. If the stop conditions are not met, the
8730-10, 8731-10 clears the waveform and
stands by again for the trigger
Measurement continues until the STOP key is
pressed or STOP signal is input to the
external control terminal.
When the "Trigger Mode" is set to "Auto",
data is loaded after a certain time even if the
trigger conditions are not met.
NOTE
Start measurement
Wait for trigger
Store the waveform
(for set data recording length)
Calculation
(Note1 )
Area comparison / Value
comparison
(Note 2)
Saves data automatically
(Note 3)
Stop measurement
YES
Are the stop conditions met?
(Note 2)
NO
(Note 1) This only applies when waveform calculation is ON.
(Note 2) This only applies when area comparison or value comparison is enabled.
If comparison is disabled, the system assumes that the stop conditions are met.
(Note 3) This only applies when the auto save function is enabled.
Start measurement
Wait for trigger
Store the waveform
(for set data recording length)
Calculation
(Note1 )
Area comparison / Value
comparison
(Note 2)
Saves data automatically
(Note 3)
YES
Are the stop conditions met?
(Note 2)
NO
The 8730-10,8731-10 continues measurement
until the STOP key is pressed or the STOP
si
nal is received.
<<Related Issues>> Relation between Trigger Mode and Stop Conditions
Waveform calculation and waveform comparisons (value and area) are
performed as shown in the flowcharts below. Operations vary depending
on the "
Trigger Mode
" (see 4.4.2) and stop conditions.
When calculation is enabled, averaging is not available. (For averaging,
see 4.2.5)