EasyManua.ls Logo

Hioki 8730-10 - Automatic Loading of Setting Data (START UP)

Hioki 8730-10
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
156
_____________________________________________________________________________________________
6.4 File Screen
______________________________________________________________________________________________
6.4.7 Automatic Loading of Setting Data (START UP)
Command: START UP
If a file with the same name already exists,
a warning message will appear
NOTE
When power is turned on, the setting file named STARTUP.SET on the
PC card is loaded automatically.
Up to 512 directories and files can be created in the root directory.
Procedure
1. Press the
FILE
key, and display the File
screen.
2. Press the left
CURSOR
key to move the
cursor to a command.
3. Select "
START UP
", then press the
ENTER
key.
4. Press the
START
key to create a setting
file named "
STARTUP.SET
". Press the
STOP
key to cancel.
Creates a file.
Cancels the creating the file.
If the amount of data is too large, the data may not be successfully saved on the PC card. For details,
see 13.3.
Creates only a startup file (STARTUP.SET) in the root directory.
If the start backup function (7.2.5) is ON, STARTUP.SET will not be loaded when power is turned
on.
If a file with the same name already exists, a warning message will appear. Press the
START
key
to overwrite the existing file. Press the
STOP key to cancel.

Table of Contents