125
_____________________________________________________________________________________________
5.4 Area Comparison Details
______________________________________________________________________________________________
5.4.3 Stop Conditions of Area Comparison
Stop Mode Details
PASS
Stops measurement when area comparison result is PASS.
FAIL
Stops measurement when area comparison result is FAIL.
PASS&FAIL
Stops measurement when area comparison result is PASS
or FAIL.
Setting Screen Area
Stop Mode (PASS, FAIL, PASS&FAIL)
Trigger Mode: When the "
Trigger Mode
"is"
Single
"
with "
Stop Mode
" set to "
FAIL
", measurement ends
when the result is FAIL.
NOTE
The 8730-10, 8731-10 may be set to stop measurement according to the
result of area comparison (PASS or FAIL). Enabling the auto save
function saves the data (see 4.2.9).
When value comparison is also conducted simultaneously, measurement
ends according to the common stop conditions (see 5.2.1).
Setting Procedure
1. Press the
COMP SETTINGS
key, and
select "
Area
"tag.
(Note 1)
2. Use the
CURSOR
key to select "
Stop
Mode", then press the
ENTER
key.
3. Select a condition, then press the
ENTER
key.
When the "Trigger Mode"issetto
"
Single", measurement continues until the
stop conditions are met and ends as soon as
these conditions are met. When the "
Trigger
Mode
" is set to "Repeat"or"Auto",
measurement continues until the
STOP
key
is pressed.
(Note 1) The "Area" tag cannot be selected
when "
FAIL Mode
"is"
OFF
" as described in
5.4.2.