209
_____________________________________________________________________________________________
8.5 Output Terminals
______________________________________________________________________________________________
T T
STORAGE
TRIG_OUT
JUDGE_OUT
OK_AREA
NG_AREA
Start
Operation o
the 8730-10
8731-10
Sto
Measurement start
Wait fo
tri
er
Storing
aveform
Comparison
rocessin
Dis
la
rocessin
Wait fo
tri
er
Storing
aveform
Trigger activated Trigger activated
Comparison time: less than 70 ms (1ch comparison), less than 80 ms
2ch com
arison
Comparison cycle: less than 200 ms (1ch comparison), less than 250 ms
2ch com
arison
<Note 1>
Clears previous
com
arison result
Out
uts com
arison result
Clears comparison
result
<Note 2>
NOTE
<Note 1>: The comparison cycles are calculated assuming that only area comparison
is conducted on a 1-kHz sine wave under the settings below.
* Time axis range: 100 μs/DIV, recording length: 10 DIV (waveform
storing time = 1 ms)
* Display format: single screen, no LAN connection, no A/B cursor display
(Note that 1ch comparison means that one channel is used by the 8730-
10 or 8731-10; 2ch comparison means that two channels are used by the
8731-10.)
Setting screen update OFF (see 5.2.2) shortens the comparison cycle as
shown below.
* 8730-10: 100 ms, 8731-10 (1ch only): 150 ms, 8731-10 (2ch): 200 ms
<Note 2>: Setting screen update OFF (see 5.2.2) inhibits display processing, but
outputs the comparison result for at least 10 ms.
OK AREA2 and NG AREA2 are onl
effective for the 8731-10.
<Timing>
1. Trigger Mode: Repeat, Auto Save: OFF