E1 Series Servo Drive Thunder Software Operation Manual Servo Drive Configuration
HIWIN MIKROSYSTEM CORP. 4-87
MD12UE01-2012
Information
If the Phase error (Elec. deg) pointer cannot converge, release Jog+ / Jog- first, and hold Jog+
/ Jog- to do the test again.
4. Select Encoder type to switch to serial encoder (EnDat). Click Jog+ and Jog- to move the
motor for direction test.
Figure 4.6.2.2.7
5. During the motor moving process, observe the right-side Phase error (Elec. deg) pointer. Wait
until the pointer converges to a specific position, “Feedback detect ok” appears and the light
lights up in green.
Figure 4.6.2.2.8

Table of Contents