Match List Rules
The data in the match list is processed by the rules listed below:
l Strings in the list will be searched in the order they appear in the list. If the list contains ABC and AB, in that order,
incoming data with ABC will match first, and the AB will have no effect.
l When a match between the first characters of the bar code and a string from the list is found, that string is stripped from
the bar code data.
l Processing the list terminates when a match is found or when the end of the list is reached.
l If the wildcard * is not specified, the string is assumed to strip from the beginning of the bar code data. The string ABC*
strips off the prefix ABC. The string *XYZ will strip off the suffix XYZ. The string ABC*XYZ will strip both prefix and
suffix together. More than one * in a configuration string is not allowed. (The User Interface will not prevent it, but results
would not be as expected, as only the first * is used in parsing to match the string.)
l The question mark wildcard ? may be used to match any single character in the incoming data. For example, the data
AB?D will match ABCD, ABcD, or AB0D, but not ABDE.
l The data collected is saved per symbology configured. The Symbology selected in the Symbologies dialog defines the
symbology for which the data is being configured.
l Note that the Code ID (if any are configured) is ignored by this dialog, regardless of the setting of Strip: Code ID in the
Symbologies dialog. According to the sequence of events (specified above), the Code ID must not be included in the bar
code data being matched, because when the matching test occurs, the Code ID has already been stripped. If Strip
Code ID is disabled, then the bar code data to match must include the Code ID. If Strip Code ID is enabled, the data
should not include the Code ID since it has already been stripped.
4-96

Table of Contents

Other manuals for Honeywell MX7 Tecton

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MX7 Tecton and is the answer not in the manual?

Honeywell MX7 Tecton Specifications

General IconGeneral
Display diagonal3.5 \
Display resolution240 x 320 pixels
Display number of colors-
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsSD
Maximum memory card size4 GB
Processor familyPXA 320
Processor frequency0.806 GHz
GPS (satellite)No
Operating system installed Windows CE 6.0
Wi-Fi standards802.11a, 802.11b, 802.11g
Bluetooth version2.0+EDR
Headphone outputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 100 %
Battery capacity2200 mAh
AC adapter output current7.4 A
Product colorBlack, Blue
Keyboard layoutAlphanumeric
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, EAN-13, GS1-128 (UCC/EAN-128), PLANET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width86 mm
Height223 mm
Weight595 g