Administration Mode
Administration mode gives full access to the mobile device, hardware and software configuration options.
The administrator must enter a valid password (when a password has already been assigned) before access to Administration
mode and configuration options are allowed. The administrator can configure the following options:
l Create/change the keystroke sequence to activate administrator access.
l Create/change the password for administrator access.
l Assign the name of the application, or applications, to lock.
l Select the command line of the application to lock.
In addition to these configuration options, the administrator can view and manage the status logs of AppLock sessions.
Administrator default values for this device:
Administrator Hotkey
Shift+Ctrl+A
Password
none
Application path and name
none
Application command line
none
End User Mode
End-user mode locks the end-user into the configured application or applications. The end user can still reboot and respond to
dialog boxes. Each application is automatically launched and runs in full screen mode when the device boots up.
The user cannot unintentionally or intentionally exit the application nor can the end user execute any other applications. Normal
application exit or switching methods and all Microsoft defined Windows CE key combinations, such as close (X) icon, File
Exit, File Close, Alt-F4, Alt-Tab, etc. are disabled. The Windows CE desktop icons, menu bars, task bar and system trays are
not visible or accessible. Task Manager is not available.
If the end-user selects File/Exit or Close from the applications menu bar, the menu is cleared and nothing else happens; the
application remains active. Nothing happens when the end-user clicks on the Close icon on the application’s title bar and the
application remains active.
Note: A few applications do not follow normal procedures when closing. AppLock cannot prevent this type of application
from closing, but is notified that the application has closed. For these applications, AppLock immediately restarts the
application which causes the screen to flicker. If this type of application is being locked, the administrator should close
all other applications before switching to end user mode to minimize the screen flicker.
Windows accelerator keys such as Alt-F4 are disabled.
4-33

Table of Contents

Other manuals for Honeywell MX7 Tecton

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MX7 Tecton and is the answer not in the manual?

Honeywell MX7 Tecton Specifications

General IconGeneral
Display diagonal3.5 \
Display resolution240 x 320 pixels
Display number of colors-
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsSD
Maximum memory card size4 GB
Processor familyPXA 320
Processor frequency0.806 GHz
GPS (satellite)No
Operating system installed Windows CE 6.0
Wi-Fi standards802.11a, 802.11b, 802.11g
Bluetooth version2.0+EDR
Headphone outputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 100 %
Battery capacity2200 mAh
AC adapter output current7.4 A
Product colorBlack, Blue
Keyboard layoutAlphanumeric
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, EAN-13, GS1-128 (UCC/EAN-128), PLANET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width86 mm
Height223 mm
Weight595 g

Related product manuals