LinearRange
Start > Settings > Control Panel > Data Collection > HHP Properties button
Default 3
Valid 1 - 6
1 specifies that the linear range that is searched for a readable label is a tight vertical range near the aimer.
6 specifies that the entire height of the image is to be searched.
AimTimer
Start > Settings > Control Panel > Data Collection > HHP Properties button
Duration of the imager aim beam in 0.1 second increments.
Default 0
Valid 0 = 50 (0 5 seconds)
If a value greater than 50 is entered, the aim duration is set to the maximum time of 5 seconds.
LeaveLightsOn
Start > Settings > Control Panel > Data Collection > HHP Properties button
Default 0
Valid 0 = Off, 1 = On
Specifies if the imager's lights and aimer should be left on during the entire decode process.
If Off, the lights are turned on only during image capture, then turned off while the imager attempts to process and decode the
bar code.
If On, the aimer and lights remain turned on during the entire process.
In Aggressive Linear Decode mode, set this parameter to 1 to improve the aimer visibility.
4-123