EasyManuals Logo

Honeywell MX7 Tecton Reference Manual

Honeywell MX7 Tecton
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
Launch Error Messages
Launch displays a message if it encounters an error during the processing of a script. It is possible to get cascading error
messages, as Launch does not stop processing the script if it encounters an error. An example of this would be a failure
creating a directory causing the failure of all files copied to that directory.
Here is a list of the possible error messages that could be given:
Error Message Given by Description
Bad wait code wait-code
Launch
LaunchCmd The wait-code wasn’t recognized
Directory Creation Failed error-
code
MkDir There was a problem encountered creating the directory
Directory Removal Failed error-
code
RmDir There was a problem encountered removing the directory
Error reading script file - An error occurred reading the script file.
File Copy Failed error-code
Copy
Fcopy
There was a problem encountered copying the file
File Delete Failed error-code Delete There was a problem encountered deleting the file
Invalid Command: command - The command wasn’t recognized
Invalid Data Length data
SetRegData
Tried to set more than 2000 byte values in a binary field
Invalid Data Type type
SetRegData
The value of the type parameter is invalid
Invalid decimal data data
SetRegData
The data field doesnt contain decimal data
Invalid hex data data
SetRegData
The data field doesnt contain hexadecimal data
Invalid Registry Key key
DelRegData
DelRegKey
SetRegData
DelRegKey
The key parameter to the command has not been recognized
Parms: Invalid Create Directory MkDir Not enough parameters were supplied.
Parms: Invalid Create Registry
Key
SetRegKey Not enough parameters were supplied.
Parms: Invalid Create Shortcut Shortcut Not enough parameters were supplied.
Parms: Invalid Delete Registry
Data
DelRegData
Not enough parameters were supplied.
Parms: Invalid Delete Registry
Key
DelRegKey Not enough parameters were supplied.
Parms: Invalid File Copy
Copy
Fcopy
Not enough parameters were supplied.
5-19

Table of Contents

Other manuals for Honeywell MX7 Tecton

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MX7 Tecton and is the answer not in the manual?

Honeywell MX7 Tecton Specifications

General IconGeneral
Display diagonal3.5 \
Display resolution240 x 320 pixels
Display number of colors-
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsSD
Maximum memory card size4 GB
Processor familyPXA 320
Processor frequency0.806 GHz
GPS (satellite)No
Operating system installed Windows CE 6.0
Wi-Fi standards802.11a, 802.11b, 802.11g
Bluetooth version2.0+EDR
Headphone outputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 100 %
Battery capacity2200 mAh
AC adapter output current7.4 A
Product colorBlack, Blue
Keyboard layoutAlphanumeric
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, EAN-13, GS1-128 (UCC/EAN-128), PLANET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width86 mm
Height223 mm
Weight595 g

Related product manuals