Revision 8 SLG 700 SmartLine Level Transmitter User’s Manual Page 167
FM Approvals
TM
Certificate #
FM16US0117X
Explosion proof with
intrinsically safe probe:
Class I Division 1, Groups A, B, C,
D with Intrinsically safe probe
Class 1, Zone 0/1 AEx ia/d IIC
Ga/Gb T5..T6
Dust Ignition Proof with
intrinsically safe probe:
Class II, Division 1, Groups E, F,
G, T5..T6 with Intrinsically Safe
Probe
Zone 21 AEx tb IIIC Db T95
o
C
Probe : Zone 20 AEx ia IIIC Da
T95
o
C
All
Note 1
Intrinsically Safe:
Class I, II, III, Division 1, Groups A,
B, C, D, E, F, G, T4
Class l, Zone 0, AEx ia IIC T4 Ga
Class I, Zone 2, AEx ic IIC T4 Gc
4-20 mA / HART
Note 2
FOUNDATION
Fieldbus / FISCO
Note 2
Non-incendive with intrinsically
safe probe:
Class I, II, III, Division 2, Groups A,
B, C, D, F, G, T5..T6 with
Intrinsically Safe Probe
Class l, Zone 2, AEx nA IIC T5..T6
Gc
Class l, Zone 2[0], AEx nA[ia Ga]
IIC T5..T6 Gc (Remote version
only.)
4-20 mA / HART
Note 1
FOUNDATION
Fieldbus / FISCO
Note 1
Enclosure: Type 4X/ IP66/ IP67.
Dual Seal in accordance with
ANSI/ISA 12.27.01
All
All

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SmartLine SLG 700 and is the answer not in the manual?

Honeywell SmartLine SLG 700 Specifications

General IconGeneral
BrandHoneywell
ModelSmartLine SLG 700
CategoryTransmitter
LanguageEnglish

Related product manuals