EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
HP P2000 G3 MSA System CLI Reference Guide 143
pager enabled|on|disabled|off
Optional.
enabled or on: Halts output after each full screen to wait for keyboard input. This is the default.
disabled or off: Output is not halted. When displaying output in XML API format, which is
intended for scripting, disable paging.
precision #
Optional. Sets the number of decimal places (1–10) for display of storage-space sizes. The default is
1.
storage-size-base 2|10
Optional. Alias for base.
storage-size-precision #
Optional. Alias for precision.
storage-size-units auto|MB|GB|TB
Optional. Alias for units.
temperature-scale celsius|c|fahrenheit|f
Optional. Sets the scale for display of temperature values:
fahrenheit or f: Temperatures are shown in degrees Fahrenheit.
celsius or c: Temperatures are shown in degrees Celsius. This is the default.
timeout #
Optional. Sets the timeout value in seconds for the login session. Valid values are 120–43200
seconds (2–720 minutes). The default is 1800 seconds (30 minutes).
units auto|MB|GB|TB
Optional. Sets the unit for display of storage-space sizes:
auto: Sizes are shown in units determined by the system. This is the default.
MB: Sizes are shown in megabytes.
GB: Sizes are shown in gigabytes.
TB: Sizes are shown in terabytes.
Based on the precision setting, if a size is too small to meaningfully display in the selected unit,
the system uses a smaller unit for that size. For example, if units is set to TB, precision is set to
1, and base is set to 10, the size 0.11709 TB is instead shown as 117.1 GB.
Example Set CLI parameters:
# set cli-parameters timeout 600 precision 2 units GB temperature-scale f
Success: Command completed successfully. - The settings were changed
successfully. (2012-01-21 11:56:08)
For scripting, display XML output in api-embed format and disable paging:
# set cli-parameters api-embed pager off
For scripting, display brief XML output in api-embed format and disable paging:
# set cli-parameters api-embed pager off brief on
Set CLI to show output in console format:
# set cli-parameters console
Success: Command completed successfully. - The settings were changed
successfully. (2012-01-21 11:56:17)
See also show cli-parameters

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures