Table 19 controllers properties
Name Type Description
durable-id string controller a
controller b
controller-id string A: Controller A.
B: Controller B.
controller-id-
numeric
string 0: B
1: A
serial-number string Serial number of the controller module.
Not Available: The controller module is down or not installed.
hardware-
version
string Controller module hardware version.
cpld-version string Complex Programmable Logic Device (CPLD) firmware version.
mac-address string Controller network port MAC address.
node-wwn string Storage system World Wide Node Name (WWNN).
ip-address string Controller network port IP address.
ip-subnet-mask string Controller network port IP subnet mask.
ip-gateway string Controller network port gateway IP address.
disks uint32 Number of disks in the storage system.
virtual-disks uint32 Number of vdisks in the storage system.
cache-memory-
size
uint32 Controller cache memory size (MB).
host-ports uint32 Number of host ports in the controller module.
drive-channels uint32 Number of expansion ports in the controller enclosure.
drive-bus-type string Controller interface to disks.
SAS
drive-bus-type-
numeric
string Numeric equivalent for drive-bus-type value.
8: SAS
status string Operational
Down
Not installed
Unknown
status-numeric string Numeric equivalents for status values.
0: Operational
1: Down
2: Not installed
3: Unknown

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals