150 Alphabetical list of commands
set enclosure
Description Sets an enclosure’s name, location, rack number, and rack position. Set these parameters to values
that help you identify and locate the enclosure. A value that contains a space must be enclosed in
double quotes.
These values are used when user interfaces show enclosure-related data; for example, in output of
the show enclosures command and in event-log entries related to enclosures.
Syntax
set enclosure
[name new-name]
[location location]
[rack-number rack-number]
[rack-position rack-position]
enclosure-number
Parameters name new-name
A new name for the enclosure. The name can include a maximum of 20 bytes, using printable UTF-8
characters except double quote, left angle bracket, comma, or backslash. A value that contains a
space must be enclosed in double quotes.
location location
The location of the enclosure. The name can include a maximum of 20 bytes, using characters
except double quote, left angle bracket, comma, or backslash. A value that contains a space must
be enclosed in double quotes.
rack-number rack-number
The number of the rack containing the enclosure, from 0–255.
rack-position rack-position
The enclosure’s position in the rack, from 0–255.
enclosure-number
The enclosure ID.
Example Set parameters for enclosure 1:
# set enclosure 1 name Storage-5 location Lab rack-number 9 rack-position 3
Success: Command completed successfully. (2012-01-21 12:03:12)
See also show enclosures

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals