HP P2000 G3 MSA System CLI Reference Guide 195
show auto-write-through-trigger
Description Shows the system’s write-through trigger settings. When a trigger condition occurs and the trigger is
enabled, the RAID controller cache mode changes from write-back to write-through. Alias: show
awt.
Syntax
show auto-write-through-trigger
Output Controller Failure
Shows whether the cache policy will change from write-back to write-through when a controller fails.
Disabled: The controller failure trigger is disabled. This is the default.
Enabled: The controller failure trigger is enabled.
Supercap Failure
Shows whether the cache policy will change from write-back to write-through when the
super-capacitor that provides backup power for cache is not fully charged or fails.
Disabled: The super-capacitor failure trigger is disabled.
Enabled: The super-capacitor failure trigger is enabled. This is the default.
CompactFlash Failure
Shows whether the cache policy will change from write-back to write-through when CompactFlash
memory is not detected during POST (Power-On Self-Test), fails during POST, or fails during controller
operation.
Disabled: The CompactFlash failure trigger is disabled.
Enabled: The CompactFlash failure trigger is enabled. This is the default.
Power Supply Failure
Shows whether the cache policy will change from write-back to write-through when a power supply
fails.
Disabled: The power-supply failure trigger is disabled. This is the default.
Enabled: The power-supply failure trigger is enabled.
Fan Failure
Shows whether the cache policy will change from write-back to write-through when a fan fails.
Disabled: The fan failure trigger is disabled. This is the default.
Enabled: The fan failure trigger is enabled.
Temperature Exceeded
Shows whether the system will shut down a controller when its temperature exceeds the critical
operating range.
Disabled: The over-temperature failure trigger is disabled. This is the default.
Enabled: The over-temperature failure trigger is enabled.
Partner Notify
Shows whether the partner controller will be notified when a trigger condition occurs.
Disabled: Notification is disabled; the partner controller will continue using its current caching
mode. This is the default.
Enabled: Notification is enabled; the partner controller will change to write-through mode for
better data protection.
Auto Write Back
Shows whether the cache mode will change from write-through to write-back when the trigger
condition is cleared.
Disabled: Auto-write-back is disabled.
Enabled: Auto-write-back is enabled. This is the default.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures