HP P2000 G3 MSA System CLI Reference Guide 417
io-modules
Properties
Table 42 io-modules properties
Name Type Description
durable-id string I/O module ID.
controller-id string A: Controller A.
B: Controller B.
controller-id-
numeric
string Numeric equivalents for controller-id values.
0: B
1: A
name string FRU name.
description string FRU long description.
part-number string FRU part number.
serial-number string FRU serial number.
revision string FRU hardware revision level.
dash-level string FRU template revision number.
fru-shortname string FRU short description.
mfg-date string Date and time, in the format year-month-day hour:minutes:seconds
(UTC), when the controller's PCBA was programmed or a power supply module
was manufactured.
mfg-date-
numeric
string Unformatted mfg-date value.
mfg-location string City, state/province, and country where the FRU was manufactured.
mfg-vendor-id string JEDEC ID of the FRU manufacturer.
position string Fan unit position, as viewed from the back of the enclosure.
Top
Bottom
Left
Right
position-
numeric
string Numeric equivalents for position values.
0: Top
1: Bottom
2: Left
3: Right
configuration-
serialnumber
string Configuration serial number.
phy-isolation string Shows whether the automatic disabling of SAS expander PHYs having high error
counts is enabled or disabled for this controller.
Enabled: PHY fault isolation is enabled. This is the default.
Disabled: PHY fault isolation is disabled.
phy-isolation-
numeric
string Numeric equivalents for phy-isolation values.
0: Enabled
1: Disabled

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures