HP P2000 G3 MSA System CLI Reference Guide 507
volume-copy-tasks
Properties
Example
# show tasks
...
<OBJECT basetype="volume-copy-tasks" name="task-volume-copy" oid="8" format="pairs">
<PROPERTY name="source-volume-name" type="string">vd02_v001</PROPERTY>
<PROPERTY name="source-volume-serial" type="string">SN</PROPERTY>
<PROPERTY name="destination-vdisk-name" type="string">vd02</PROPERTY>
<PROPERTY name="destination-pool-name" type="string">vd02</PROPERTY>
<PROPERTY name="destination-vdisk-serial" type="string">SN</PROPERTY>
<PROPERTY name="destination-pool-serial" type="string">SN</PROPERTY>
<PROPERTY name="destination-volume-prefix" type="string">vd02_v001_01</PROPERTY>
<PROPERTY name="include-modified-data" type="string">preserved</PROPERTY>
<PROPERTY name="last-created" type="string"></PROPERTY>
</OBJECT>
...
Table 92 volume-copy-tasks properties
Name Type Description
source-volume-
name
string Source volume name.
source-volume-
serial
string Source volume serial number.
destination-
vdisk-name
string Destination vdisk name.
destination-
vdisk-serial
string Destination vdisk serial number.
destination-
volume-prefix
string Label that identifies copies created by this task. Volume names have the format
prefix_s#, where # starts at 001.
include-
modified-data
string modified: The copy includes modified snapshot data.
preserved: The copy excludes modified snapshot data.
last-created string Name of the last volume created by the task, or blank.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals