EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
HP P2000 G3 MSA System CLI Reference Guide 179
set snap-pool-threshold
Description Sets the percentages of snap-pool space used that trigger the warning and error threshold policies.
Three thresholds are defined:
Warning: The snap pool is moderately full. When this threshold is reached, an event is generated
to alert the administrator.
Error: The snap pool is nearly full and unless corrective action is taken, snapshot data loss is
probable. When this threshold is reached, an event is generated to alert the administrator and
the associated snap-pool policy is triggered.
Critical: The snap pool is 98% full and data loss is imminent. When this threshold is reached, an
event is generated to alert the administrator and the associated snap-pool policy is triggered.
Syntax
set snap-pool-threshold
[warning #%]
[error #%]
snap-pool
Parameters warning #%
The percent of snap-pool space used that triggers the warning threshold policy. This value must be
less than the error threshold value. The default is 75%.
error #%
The percent of snap-pool space used that triggers the error threshold policy. This value must be less
than 98%. The default is 90%.
snap-pool
Name or serial number of the snap pool to set the threshold for. For volume syntax, see Command
syntax on page 22.
Example Set the warning and error thresholds for snap pool SP1:
# set snap-pool-threshold warning 60% error 85% SP1
Success: Command completed successfully. (2012-01-21 12:33:46)
See also set snap-pool-policy
show snap-pools

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures