show ports
Description Shows information about host ports on both controllers. This command shows the same information
as the show host-parameters command.
Syntax
show ports
Output Ports
Controller ID and port number.
Media
FC(P): Fibre Channel Point-to-Point (public or private).
FC(L): Fibre Channel-Arbitrated Loop.
FC(-): Not applicable, as when the port is disconnected.
SAS: Serial Attached SCSI.
iSCSI: Internet SCSI.
Target ID
Port WWN or IQN.
Status
Whether the port is operational, has a problem, or is disconnected.
Speed (A)
Actual host-port link speed, or blank if not applicable.
Speed (C)
Configured host-port link speed:
FC: Auto, 8Gb, 4Gb, or 2Gb (Gbit/sec).
iSCSI: Auto or 1Gb (Gbit/sec).
Blank if not applicable.
Health
OK
Degraded
Fault
N/A
Health Reason
If Health is not OK, this field shows the reason for the health state.
Health Recommendation
If Health is not OK, this field shows recommended actions to take to resolve the health issue.
Topo (C)
FC and SAS only. Configured topology.
Width
SAS only. Number of PHY lanes in the SAS port.
PID
FC only. Primary loop ID, or blank if not applicable.
IP-Ver
iSCSI only. IP version: IPv4 or IPv6.
PIP
iSCSI only. Primary IP address.
PIP-Gateway
iSCSI only. Primary gateway IP address.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals