EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #519 background imageLoading...
Page #519 background image
HP P2000 G3 MSA System CLI Reference Guide 519
A Settings changed by restore defaults
This appendix summarizes the system settings that result from using the restore defaults command.
Table 99 Settings changed by restore defaults
Setting Value
System information settings:
System name
System contact
System location
System information
Uninitialized Name
Uninitialized Contact
Uninitialized Location
Uninitialized Info
Management protocols settings:
CLI/Telnet
CLI/SSH
FTP
SNMP
WBI/HTTP
WBI/HTTPS
SMI-S
Unsecure SMI-S
Debug
In-band SES
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
Enabled
Users All configured users are deleted and replaced with default user definitions
and default settings:
User: manage; password: !manage
User: monitor; password: !monitor
User: ftp; password: !ftp
Temperature scale: Celsius
Timeout: 30 minutes
CLI/Telnet timeout 30 minutes
Tasks and schedules (preserved)
1
Remote system definitions (preserved)
2
MC debug logs (preserved)
3
SC event logs (preserved)
Time/date and NTP settings (preserved)
4
Network IP settings If addressing mode is Manual, IP values are preserved. If addressing mode
is DHCP, IP values are released.
5
Network Ethernet-switch settings
Link speed
Duplex mode
Auto-negotiation
100mbps
Full
Enabled
SNMP settings:
SNMP
SNMP trap notification level
SNMP trap host IPs
SNMP read community
SNMP write community
Disabled
none
0.0.0.0
public
private

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals