HP P2000 G3 MSA System CLI Reference Guide 289
show snmp-parameters
Description Shows SNMP settings for event notification.
Syntax
show snmp-parameters
Output SNMP Trap Notification Level
crit: Only Critical events are sent as traps.
error: Error and Critical events are sent as traps.
warn: Warning, Error, and Critical events are sent as traps.
info: All events are sent as traps.
none: No events are sent as traps and traps are disabled.
SNMP Trap Host IP#
IP address of each trap host.
SNMP read community
Community string for read-only access (not shown to Monitor users).
SNMP write community
Community string for write access (not shown to Monitor users).
Example Show SNMP notification settings:
# show snmp-parameters
SNMP Trap Notification Level: crit
SNMP Trap Host IP1: 172.22.4.171
SNMP Trap Host IP2: 0.0.0.0
SNMP Trap Host IP3: 0.0.0.0
SNMP read community: public
SNMP write community: private
Success: Command completed successfully. (2012-01-19 15:27:59)
Basetypes snmp-parameters
status
See also set snmp-parameters
set protocols
show protocols

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals