146 Alphabetical list of commands
set debug-log-parameters
Description For use by or with direction from a service technician.
Sets the types of debug messages to include in the Storage Controller debug log.
Syntax
set debug-log-parameters message-type+|- [...]
Parameters message-type+|-
One of the following message types, followed by a plus (+) to enable or a minus (-) to disable
inclusion in the log:
awt: Auto-write-through cache triggers debug messages. Disabled by default.
bkcfg: Internal configuration debug messages. Enabled by default.
cache: Cache debug messages. Enabled by default.
capi: Internal Configuration API debug messages. Enabled by default.
capi2: Internal Configuration API tracing debug messages. Disabled by default.
disk: Disk interface debug messages. Enabled by default.
dms: Snapshot feature debug messages. Enabled by default.
emp: Enclosure Management Processor debug messages. Enabled by default.
fo: Failover and recovery debug messages. Enabled by default.
fruid: FRU ID debug messages. Enabled by default.
hb: Not used.
host: Host interface debug messages. Enabled by default.
init: Not used.
ioa: I/O interface driver debug messages (standard). Enabled by default.
iob: I/O interface driver debug messages (resource counts). Disabled by default.
ioc: I/O interface driver debug messages (upper layer, verbose). Disabled by default.
iod: I/O interface driver debug messages (lower layer, verbose). Disabled by default.
mem: Internal memory debug messages. Disabled by default.
misc: Internal debug messages. Enabled by default.
msg: Inter-controller message debug messages. Enabled by default.
mui: Internal service interface debug messages. Enabled by default.
ps: Not used.
raid: RAID debug messages. Enabled by default.
rcm: Removable-component manager debug messages. Disabled by default.
res2: Internal debug messages. Disabled by default.
resmgr: Reservation Manager debug messages. Disabled by default.
Example Include RAID and cache messages, exclude EMP messages, and leave other message types
unchanged:
# set debug-log-parameters raid+ cache+ emp-
Success: Command completed successfully. - Debug-log parameters were changed.
(2012-01-21 11:58:38)
See also show debug-log-parameters

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals