HP P2000 G3 MSA System CLI Reference Guide 157
On a system with FC ports, set the link speed to 4 Gbit/sec for ports A1 and B1; set controller A
ports to request loop ID 5 and controller B ports to request loop ID 32; and suppress the confirmation
prompt:
# set host-parameters speed 4g ports a1,b1 fibre-loop-id 5,32 noprompt
Info: Changes to FC loop IDs will not take effect until the affected Storage
Controller is rebooted.
Success: Command completed successfully. - The host parameters were changed
successfully. (2012-01-21 15:46:14)
On a system with iSCSI ports, for port A3 change the IP address:
# set host-parameters ip 10.134.50.6 port a3 iscsi-ip-version ipv4
WARNING: This change will take effect immediately. Changes may affect access to
data. Are you sure? yes
Success: Command completed successfully. - The host parameters were changed
successfully. (2012-01-21 15:46:51)
Specify that iSCSI ports will use IPv6 addressing:
# set host-parameters iscsi-ip-version ipv6
Success: Command completed successfully. - iSCSI parameter(s) were changed
successfully. (2012-01-21 15:47:30)
See also restart
set iscsi-parameters
show host-parameters

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals