EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #188 background imageLoading...
Page #188 background image
188 Alphabetical list of commands
temperature-scale celsius|c|fahrenheit|f
Optional. Sets the scale for display of temperature values:
fahrenheit or f: Temperatures are shown in degrees Fahrenheit.
celsius or c: Temperatures are shown in degrees Celsius. This is the default.
timeout #
Optional. Sets the timeout value in seconds for the login session. Valid values are 120–43200
seconds (2–720 minutes). The default is 1800 seconds (30 minutes).
trap-host IP-address
Optional. For an SNMPv3 user whose interface parameter is set to snmptarget, this specifies
the IP address of the host that will receive SNMP traps.
type novice|standard|advanced|diagnostic
Optional. Identifies the user’s experience level. The default is standard.
units auto|MB|GB|TB
Optional. Sets the unit for display of storage-space sizes:
auto: Sizes are shown in units determined by the system. This is the default.
MB: Sizes are shown in megabytes.
GB: Sizes are shown in gigabytes.
TB: Sizes are shown in terabytes.
Based on the precision setting, if a size is too small to meaningfully display in the selected unit,
the system uses a smaller unit for that size. For example, if units is set to TB, precision is set to
1, and base is set to 10, the size 0.11709 TB is instead shown as 117.1 GB.
name
Specifies the user account to change. Names are case sensitive.
Example Change the temperature scale and accessible interfaces for user jsmith:
# set user jsmith temperature-scale f interfaces wbi,cli
Success: Command completed successfully. - The settings were changed
successfully. (2012-01-21 14:39:50)
Change the password for user JDoe:
# set user JDoe password Abcd%1234
Success: Command completed successfully. - The settings were changed
successfully. (2012-01-21 14:39:56)
Change the authentication type for SNMPv3 user Traps:
# set user Traps authentication-type MD5 password Snmp%Trap
Success: Command completed successfully. - The settings were changed
successfully. (2012-01-12 14:40:10)
For the only CLI user with the manage role, try to reduce the role to monitor:
# set user SysAdmin roles monitor
Error: At least one CLI user must retain configuration privileges at all times.
(2013-10-31 14:10:47)
See also set password
show users

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals