Cache Write Policy
If a volume is specified, its cache write policy:
write-back: Write-back caching does not wait for data to be completely written to disk before
signaling the host that the write is complete. This is the default and preferred setting for a
fault-tolerant environment because it improves the performance of write operations and
throughput.
write-through: Write-through caching significantly impacts performance by waiting for data
to be completely written to disk before signaling the host that the write is complete. Use this
setting only when operating in an environment with low or no fault tolerance.
Cache Optimization
If a volume is specified, its cache optimization mode:
standard: Optimizes cache for both sequential and random reads. Appropriate for
applications that read and write small files in random order, such as transaction-based and
database update applications. This is the default.
Read Ahead Size
If a volume is specified, its read-ahead cache setting:
Disabled: Read-ahead caching is disabled.
Default: One chunk for the first access in a sequential read and one stripe for all subsequent
accesses.
Maximum: Maximum read-ahead size calculated by the controller.
64 KB, 128 KB, 256 KB, 512 KB, 1 MB, 2 MB, 4 MB, 8 MB, 16 MB, or 32 MB: Size selected
by a user.
Example Show the cache parameters for the system and for volume V1:
# show cache-parameters V1
System Cache Parameters
-----------------------
Operation Mode: Active-Active ULP
Controller A Cache Parameters
-----------------------------
Write Back Status: Enabled
CompactFlash Status: Installed
Cache Flush: Enabled
Controller B Cache Parameters
-----------------------------
Write Back Status: Enabled
CompactFlash Status: Installed
Cache Flush: Enabled
Volume Cache Parameters
-----------------------
Serial Number: SN
Name: V1
Cache Write Policy: write-back
Cache Optimization: standard
Read Ahead Size: Default
Success: Command completed successfully. (2012-01-18 14:31:19)
Basetypes cache-settings
cache-parameter
status

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures