HP P2000 G3 MSA System CLI Reference Guide 227
FRU P/N
Part number of the field-replaceable unit (FRU) that contains the component.
FRU S/N
Serial number of the FRU that contains the component.
Add'l Data
Additional data, if applicable:
• addr=: For a disk, the slot address.
• temp=: For a temperature sensor, the temperature.
• voltage=: For a voltage sensor, the voltage.
• --: No data.
Example Show enclosure status:
# show enclosure-status
Chassis Vendor Product ID CPLD EMP A CH:ID Rev EMP B CH:ID Rev
WWPN Status
-------------------------------------------------------------------------------
SN vendor product 21 00:031 1115 01:031 1115
WWPN OK
-------------------------------------------------------------------------------
Type # Status FRU P/N FRU S/N Add'l Data
-----------------------------------------------------
FAN 01 OK PN SN --
...
PSU 01 OK PN SN --
...
Temp 01 OK PN SN temp=37 C
...
Voltage 01 OK PN SN voltage=11.86
...
Disk 01 OK PN SN addr=0
...
-----------------------------------------------------
Success: Command completed successfully. (2012-01-18 15:01:36)
Basetypes • ses
• enclosure-components
• status
See also • show enclosures