HP P2000 G3 MSA System CLI Reference Guide 277
Example Show the condition of SAS port connections in a two-enclosure system:
# show sas-link-health
Encl Ctlr Name Status Health
Health Reason Health Recommendation
-----------------------------------------------------------------------------
1 A Out Port Up OK
1 B Out Port Up OK
-----------------------------------------------------------------------------
Encl Ctlr Name Status Health
Health Reason
Health Recommendation
-----------------------------------------------------------------------------
2 A Out Port Disconnected N/A
No drive enclosure is connected to this expansion port. This is normal if
this is the last (or only) enclosure in the cabling sequence of the system.
- No action is required.
2 A In Port Up OK
2 B Out Port Disconnected N/A
No drive enclosure is connected to this expansion port. This is normal if
this is the last (or only) enclosure in the cabling sequence of the system.
- No action is required.
2 B In Port Up OK
-----------------------------------------------------------------------------
Success: Command completed successfully. (2012-01-19 10:10:13)