438 XML API basetype properties
Example
# show power-supplies
...
<OBJECT basetype="power-supplies" name="power-supplies" oid="1" format="rows">
<PROPERTY name="durable-id" type="string">psu_1.1</PROPERTY>
<PROPERTY name="enclosure-id" type="uint32">1</PROPERTY>
<PROPERTY name="serial-number" type="string">SN</PROPERTY>
<PROPERTY name="description" type="string">description</PROPERTY>
<PROPERTY name="name" type="string">PSU 1, Left</PROPERTY>
<PROPERTY name="revision" type="string">01</PROPERTY>
<PROPERTY name="model" type="string">FRUKE01</PROPERTY>
<PROPERTY name="vendor" type="string">0x0301</PROPERTY>
<PROPERTY name="location" type="string">Enclosure 1 - Left</PROPERTY>
<PROPERTY name="position" type="string">Left</PROPERTY>
<PROPERTY name="position-numeric" type="string">0</PROPERTY>
<PROPERTY name="part-number" type="string">FRUKE01</PROPERTY>
<PROPERTY name="dash-level" type="string">01</PROPERTY>
<PROPERTY name="fru-shortname" type="string">FRUKE01</PROPERTY>
<PROPERTY name="mfg-date" type="string">2007-01-18 22:38:18</PROPERTY>
<PROPERTY name="mfg-date-numeric" type="string">1169159898</PROPERTY>
<PROPERTY name="mfg-location" type="string">Milpitas,CA,US</PROPERTY>
<PROPERTY name="mfg-vendor-id" key="true" type="string">0x0301</PROPERTY>
<PROPERTY name="configuration-serialnumber" type="string">SN</PROPERTY>
<PROPERTY name="dc12v" type="uint32">1249</PROPERTY>
<PROPERTY name="dc5v" type="uint32">551</PROPERTY>
<PROPERTY name="dc33v" type="uint32">343</PROPERTY>
<PROPERTY name="dc12i" type="uint32">0</PROPERTY>
<PROPERTY name="dc5i" type="uint32">0</PROPERTY>
<PROPERTY name="dctemp" type="uint32">45</PROPERTY>
health string OK
Degraded
Fault
Unknown
health-numeric string Numeric equivalents for health values.
0: OK
1: Degraded
2: Fault
3: Unknown
health-reason string If Health is not OK, the reason for the health state.
health-
recommendation
string If Health is not OK, the recommended actions to take to resolve the health issue.
status string Power supply status.
Up
Warning
Error
Not Present
Unknown
status-numeric string Numeric equivalents for status values.
0: Up
1: Warning
2: Error
3: Not Present
4: Unknown
Table 53 power-supplies properties (continued)