EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
54 Alphabetical list of commands
noprompt
Optional in console format; required for XML API format. Suppresses the prompt to revert the
transaction if the command fails, which requires a yes or no response. If this parameter is specified
and the command fails, the transaction is automatically reverted.
nowait
Optional. Adding a volume to a replication set can take the Storage Controller several minutes to
complete. This parameter allows that processing to continue in the background so the Management
Controller can process other commands.
primary-address ip=address|iqn=IQN|wwn=WWN
Optional. Specifies host ports on the local system by IP address, World Wide Node Name, or World
Wide Port Name. An IP address value can include a port number; for example, 10.134.2.1:3260.
Multiple values must be separated by commas and no spaces; for example:
ip=10.134.2.1,10.134.2.2.
priority low|medium|high
Optional. Priority of the replication process on the replication volumes: low, medium, or high.
remote-system system
Optional; required if the remote-vdisk or remote-volume parameter specifies a destination in
a remote system. Name or network-port IP address of the remote system.
remote-vdisk vdisk
Optional. Name or serial number of the vdisk that the remote volume and snap pool should be
created in. If the vdisk is on a remote system:
You must specify the remote-system parameter.
If the local and remote MCs can communicate, you can specify a name or serial number;
otherwise, you must specify a serial number.
The snap pool created on the secondary system will be the same size as the snap pool on the
primary system.
remote-volume volume
Optional; do not use with the remote-vdisk parameter. Name or serial number of a
replication-prepared volume to use as a secondary volume. If the volume is on a remote system and
the local and remote MCs can communicate, you can specify a name or serial number; otherwise,
you must specify a serial number.
reserve size[B|KB|MB|GB|TB|KiB|MiB|GiB|TiB]
Optional. Specifies the size of the snap pool to create if the primary volume is a standard volume.
The size value uses the current base, as shown by the show cli-parameters command. The unit
can be specified as follows.
If base 2 is in use: B (bytes), KiB (kibibytes), MiB (mebibytes), or GiB (gibibytes).
If base 10 is in use: B (bytes), KB (kilobytes), MB (megabytes), or GB (gigabytes).
If no unit is specified, the unit is 512-byte blocks. If this parameter is omitted, the size will be either
20% of the volume size or 5.37 GB, whichever is larger.
NOTE: In rare cases, a large amount of I/O can cause a snap pool that is too small to fill quickly.
This can result in all snapshots being deleted due to the snap pool running out of space. Create snap
pools of at least 50 GB to avoid this situation.
secondary-address ip=IPs|wwnn=WWNNs|wwpn=WWPNs
Optional if the MCs can communicate and the remote-system parameter is specified; required if
the MC cannot communicate and a replication-prepared volume is specified. Specifies host ports on
the remote system by IP address, World Wide Node Name, or World Wide Port Name. An IP
address value can include a port number; for example, 10.134.2.1:3260. Multiple values must be
separated by commas and no spaces; for example: ip=10.134.2.1,10.134.2.2.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures

Related product manuals